Heat-exchanger preliminary sizing
Set the process duty, calculate the temperature driving force, then estimate area using the selected overall coefficient.
Steady Sensible Heat Balance → Heat Exchanger LMTD → Heat Exchanger Area
Engineering calculator reviewed for preliminary design use · Last updated: March 2026
Thermal design calculations are essential for energy-efficient process plant operation. These tools support heat exchanger sizing, insulation analysis, and thermal balance calculations.
Thermal design calculations are essential for energy-efficient process plant operation. From sizing heat exchangers to estimating insulation requirements, these tools support engineers in making informed thermal design decisions during all project phases.
A typical thermal design workflow starts with heat balance to determine total duty, then uses LMTD to find the mean temperature difference, and finally calculates required heat transfer area. For batch systems, use the Tank Heating calculator. Insulation calculations help optimize energy costs and ensure personnel safety.
These calculators assume steady-state conditions, constant fluid properties, and no phase change unless specifically noted. For systems with boiling, condensation, or supercritical conditions, additional correlations are required. Fouling factors should be applied per TEMA standards.
Use Heat Balance when the unknown is duty or utility demand. Use LMTD when terminal temperatures are known, and Heat Exchanger Area after you have a duty, LMTD, and an overall coefficient. Choose Tank Heating for time-dependent batch heating, Pipe Insulation for surface heat loss, and Steam Properties for saturated-steam reference values.
Set the process duty, calculate the temperature driving force, then estimate area using the selected overall coefficient.
Steady Sensible Heat Balance → Heat Exchanger LMTD → Heat Exchanger Area
Confirm steam reference conditions, estimate batch heat-up time, and check distribution-line heat loss.
Saturated Steam Properties → Tank Heating Time → Pipe Insulation Heat Loss
Add fouling resistance to the overall heat transfer coefficient. Typical values are 0.0002 m²·K/W for clean water and 0.0009 m²·K/W for heavy hydrocarbons. Use TEMA or project-specific values.
These tools handle sensible heat duty. For condensation, the latent heat portion requires separate calculation using condensation correlations. Use the Heat Balance for the sensible part and add latent heat separately.
For preliminary estimation and educational use only. Results may depend strongly on assumptions, input data, fluid or material properties, and the range of validity of the underlying equation. Verify critical calculations independently and follow the applicable code, specification, and formal engineering review process before using any result for design, procurement, fabrication, operation, or safety decisions.